Description
The device, as auxiliary infusion device, equipped with independent dual-core CPU, intelligently controls the whole process of infusion. With peristaltic pump as power source, real-time monitoring by multiple sensors, and multiple alarm functions, the device can meet the requirements of infusion under various circumstances, overcome the shortage of gravity infusion, meet the needs of clinical intravenous infusion and improve the accuracy of intravenous infusion.
Important Properties
1. Stored infusion parameters: Setup and storage of flow rate accuracy of 5 types of IV sets
2.Adjustable scope of infusion flow rate: Infusion flow rate (adjustable from 1ml/h to 1200ml/h) can meet the needs in different situations.
3.Operated with its internal battery: Don’t worry about interruption of transfusion during patient
4.Transport or sudden power outage. Batteries can be externally removed, easy for transportation and maintenance.
5.Dual CPU structure: Reliable system architecture able to ensure the security of system.
6.Ultrasonic air bubble detector: Ultrasonic detection technique which ensures accurate air bubble detection, is applicable to various liquids and IV sets.
7.Tube occlusion test: Occlusion alarm pressure range: 3 levels, easier to use
8.Dosage mode(Body weight mode):Able to turn into a proper flow rate of infusion automatically when body weight, drug and solution volume are entered
9.Basic performance: Flow rate accuracy
We care for your pets~
Double CPU to ensure higher reliability


Module Design for easier local service in any countries
Competitive Advantage:
1.Reliable quality, less service.
2.Classic numeric key button for easiest operation, within 10 meters doctor & nurse can learn how to use it.
3.100-240V wide voltage range to match different markets & hospitals.
4.One-button night mode for patient’s comfortable rest at night.
5.Except for normal alarms, we cover more alarms than competitors like even Door Open, low temperature etc.
6.For drop rate, Micro & Macro is both available.
7.One page LCD screen for clear vision of all parameters.
8. Mostly for better & easy clinical use.
9.For specifications, we cover most clinical use parameters, and similar to competitor brand specifications.
10.8 hours + battery support.
11. ISO & CE Certificate
Specifications
Model No./ Parameters | IPA112 | |
Infusion Principle | Fingertip Peristaltic Pump | |
I.V.Set Compatibility | Open System, match all brands of qualified PVC,TPE I.V.sets with external diameter of 3.8mm-4.2mm | |
Range of Flow Rate | 0.1-1200ml/h | |
Infusion Mode | Rate, Rate-Time, Rate-Volume, Time-Volume, Drop-Volume, Drop-Time | |
Drug Library | 20 drug list with drug code display | |
Purge/Bolus Rate | 1-1200ml/h,defalut 800ml/h, step by 1ml/h | |
Single Bolus Volume | 1.0-10ml Adjustable, default 3 ml | |
Time Preset | 00: 01~99: 59 (Hour: Min) | |
Volume Range | 1~9999ml | |
Drop Range | 1-400d/min, step by 1 drop | |
Accuracy | ±5% | |
Total Volume Infused | 0-9999 ml | |
Occlusion Pressure | High | 40 KPa±20KPa |
Middle | 60 KPa±20KPa | |
Low | 100KPa±20KPa | |
Air in line Detection | Ultrasonic wave | |
Visible & Audible Alarms | Air in line, Down Stream Occlusion, Door Open, VTBI Completion, Near Completion, Low Battery, Battery Exhausted, Low Temperature, Motor Malfunction, A.C Disconnection, A.C connection, I.V set dislocation, MPU Error, Batery Charing, Battery Charing Completion, Circuit Malfunction | |
K.V.O Rate | 1ml/h-5ml/h, default value 1ml/h, can be programmed by user step 0.1ml/h | |
Internal Battery | Lithium battery, 11.1/2000mAh, more than 4 hours working back up | |
Power Consumption | 30VA | |
Power | AC 100V-240V 50HZ/60HZ | |
Classification | Class II, Type CF, IPX4 | |
Dimension & Weight | 13×17.5×23 cm;2Kg | |
Optional Function | Ambulance DC 12V |