12.1 Inch Color TFT LCD Multi-Parameter Cardiac Monitor GT6800-15


Description

Portable patient monitor is adaptable to adult, pediatric and neonatal usage. It can monitor vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP. It integrates parameter measuring modules, display and recorder in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient. Large high-resolution display provides clear view of 5 waveforms and full monitoring parameters.

Portable Patient Monitor performs monitoring of:

ECG

Heart Rate (HR)

2-channel ECG waveforms

S-T segment analysis

Arrhythmia(optional)

RESP

Respiratory Rate (RR)

Respiration Waveform

SpO2

Oxygen Saturation (SpO2), Pulse Rate (PR)

SpO2 Plethysmogram

NIBP

Systolic Pressure (NS), Diastolic Pressure (ND), Mean Pressure (NM)

TEMP

Temperature DATA

IBP

IBP DATA

Providing extensive functions as visual & audible alarm, storage and report printout for trend data, NIBP measurements, and alarm events, and drug dose calculation function is provided either. Our monitor is a user-friendly device with operations conducted by a few buttons on the front panel and a rotary knob.


undefined

6 Parameters: ECG,RESP, SpO2, PR, NIBP, Dual-channel TEMP.

Optional: IBP, EtCO2, Printer

    

Backside of Patient Monitor

Built-in rechargeable li-battery

1.2.1 背面照
1656392667301621
Optional Function Thermal Printer
Easy to carry
1656392905832171
Competitive Advantage:
Features

High resolution 12.1'' color TFT display

Light weight, Portable and Suitable for adult, pediatric and neonatal patient

Arrhythmia analysis and S-T segment analysis

ECG waveforms of 7-leads display on the same screen

72-hours graphic and tabular trends of all parameters

72 alarm events of all parameters recall

Data and waveforms color be adjustable

Upgraded Weak crown index monitoring

Various interfaces: standard, trend, oxyCRG and big font screen

Built-in rechargeable li-battery

Wire/wireless center monitoring system, applicable to ICU/CCU/OR etc

Effcient resistance to interference of defibrillator and electrosurgical unit

LFG technology for SPO2, ensure SPO2 and PR more precise

Language: English, Spanish, Italian, German, French, Chinese

Specifications

ECGLead type3-lead, 5-lead (Ⅰ、Ⅱ、Ⅲ、aVF、aVR、aVL、V1--6)
Sweep speed12.5mm/s, 25mm/s, 50mm/s
Accuracy±1% or ±1bpm
Heart Rate rangeAdult: 15 - 300bpm;
Newborn/Child:15 - 350 bpm
S-T detection-2.0mV-+2.0mV
Arrhythmia analysisYES
Gain×1 、×2 、×4、×0.5
RangeAdult:15 ~ 300 bpm;
Neo/Ped: 15 ~ 350 bpm
CMRRMonitor:>100db;
Operation:>100db;
Diagnosis:>90db
Alarmaudible and visual alarm,
alarm events recallable
NIBPMethodOscillometry
Operation modeManual/Automatic/STAT
Measurement UnitmmHg/KPa
Measurement typesSystolic,
Diastolic,
Mean
Over Pressure ProtectionDouble safety protection Adult Mode:300 mmHg
Pediatric Mode:240 mmHg
Neonatal Mode:150 mmHg
Measuring and alarm RangeAdult ModelSystolic pressure:40-270mmHg;
Diastolic pressure:10-215mmHg
MEAN:20-235mmHg
Pediatric ModeSystolic pressure:40-200mmHg;
Diastolic pressure:10-150mmHg
MEAN:20-165mmHg
Neonatal ModeSystolic pressure:40-135mmHg;
Diastolic pressure:10-100mmHg
MEAN:20-110mmHg
Static Pressure Range0-300mmHg
Static Pressure accuracy±3mmHg
Blood Pressure accuracymaximum average error: ±5mmHg
maximum standard deviation: 8mmHg
Alarm preset range and errorAlarm:audible and visual alarm
Systolic pressure:Upper Limit 40~250mmHg;lower limit 10~220mmHg
Diastolic pressure:Upper Limit20~250mmHg;lower limit: 10~220mmHg
SPO2Range0-100%, ±2 DIGIT
0-69%: undefined
Measurement error70-100%; ±2 DIGIT
0-69%: undefined
Resolution1%
Pulse rate20 - 300BPM
Alarmaudible and visual alarm
Alarm preset range and errorUpper Limit: 20%~100%;
Lower Limit:10%~99%;
RESPMeasuring and Alarm RangeAdult: 7-120BrPM;
Newborn/Child: 7-150 BrPM
Accuracy±2 BrPM
Resolution1 BrPM
Gain Selection×0.5,×1,×2,×4
Alarmaudible and visual alarm
Alarm preset range and errorUpper Limit: 10 ~ 100 BrPM
Lower Limit: 0 ~ 99 BrPM
TEMPMethodHighly sensitive thermistor probe
Channel2 (T1, T2)
Measuring and Alarm Range0℃ - 45℃
Resolution0.1℃
Precision±0.1°C (not including the probe’s error)
Alarm preset range and errorUpper Limit: 20.1℃ ~ 45℃, Adjustable
Lower Limit: 20℃ ~ 44.9℃, Adjustable
Alarmaudible and visual alarm
PowerBatteryBuilt-in Rechargeable Li battery
External AC220V, 50Hz, 1A
Working Temperature5℃ ~ 40℃
Working Humidity≤85% (Relative humidity, non-condensing)
Storage Temperature-20℃ ~ +55℃
Storage Humidity≤95% (Relative humidity, non-condensing)
Altitude86.0kPa ~ 106.0 kPa (Working Situation)
Power Consumption≤70VA
Size and WeightSize Monitor300mm× 280mm ×160mm
Weight Monitor2.5 kg
Safety StandardIEC60601 – 1、UL2601,GB9706.1-2007、GB9706.9-2008、GB9706.25-2005、YY0667-2008、YY0668-2008、YY0709-2009,YY0784-2010.